I-Light Network Operations Report
2024-12-20 - 2025-01-02

I-Light Network Operations Center

Unscheduled Outages Summary

Incident Number Customer Impact Network Impact Title Outage Type Source of Impact Current State Start Time (UTC) End Time (UTC) Duration

INC0197691 2 - High2 - High Brief Outage - I-Light Backbone EVVL-NEWAUndetermined Undetermined Closed 2024-12-20 14:46:10 2024-12-20 14:46:32 0 days 0 hr 0 min
INC0198510 2 - High2 - High Outage Resolved - I-Light Backbone KOKM-MARNCircuit - Damaged Fiber Vendor Closed 2024-12-31 04:48:59 2024-12-31 09:36:59 0 days 4 hr 48 min
INC0198532 2 - High2 - High Brief Outage - I-Light Backbone GARY-SBNDUndetermined Undetermined Closed 2024-12-31 14:59:01 2024-12-31 14:59:21 0 days 0 hr 0 min

Unscheduled Outages Detail


Ticket No.:INC0197691
Subject:Brief Outage - I-Light Backbone EVVL-NEWA
Source Of Impact: Undetermined
Affected:ILN-EVVL-NEWA-100GE-24292
Backbone EVVL-NEWA
Hanover College
I-Light
I-Light Engineering & Support
Indiana State University
Indiana State University Federal Hall
Indiana University Southeast
Indiana University Southeast - Water Tower Square
IU School of Medicine Health Science
Ivy Tech Evansville
Ivy Tech Madison
Ivy Tech Sellersburg
Ivy Tech Terre Haute
Oakland City University
Purdue Polytechnic New Albany
Rose Hulman Institute of Technology
St. Mary of the Woods College
University of Evansville
University of Southern Indiana
Vincennes University
Vincennes University - Aviation
Vincennes University - Fort Branch
Vincennes University - Indiana Deaf School
Vincennes University - Jasper
Vincennes University - Lebanon
Vincennes University - Plainfield
Wabash College
Current State:Closed
Start Time:2024-12-20 14:46:10
End Time:2024-12-20 14:46:32
Outgoing Notification TextBackbone EVVL-NEWA is available following a brief outage. I-Light network engineers have been contacted to investigate. The reason for outage is undetermined.


Ticket No.:INC0198510
Subject:Outage Resolved - I-Light Backbone KOKM-MARN
Source Of Impact: Vendor
Affected:ILN-KOKM-MARN-FIBR-1523
Indiana University Kokomo
Ivy Tech Kokomo
Purdue Polytechnic Kokomo
Current State:Closed
Start Time:2024-12-31 04:48:59
End Time:2024-12-31 09:36:59
Outgoing Notification TextBackbone KOKM-MARN is now available. Zayo engineers report fiber was damaged by a car accident. All repairs are complete, and no further outages are expected.


Ticket No.:INC0198532
Subject:Brief Outage - I-Light Backbone GARY-SBND
Source Of Impact: Undetermined
Affected:ILN-GARY-SBND-DWDM-24101
Backbone GARY-SBND
Anderson University
Ball State University
Earlham College
Goshen College
Grace College
Holy Cross College
Huntington University
Huntington University-Parkview
Indiana GigaPOP
Indiana Institute of Technology Ft. Wayne
Indiana University East
Indiana University Fort Wayne
Indiana University Northwest
Indiana University South Bend
Indiana Wesleyan University
Ivy Tech Anderson
Ivy Tech Anderson 60th Street
Ivy Tech Connersville
Ivy Tech East Chicago
Ivy Tech Elkhart
Ivy Tech Fort Wayne
Ivy Tech Lafayette
Ivy Tech Lawrenceburg
Ivy Tech Marion
Ivy Tech Michigan City
Ivy Tech Muncie
Ivy Tech Northwest
Ivy Tech Richmond
Ivy Tech South Bend
Ivy Tech Valparaiso
Ivy Tech Warsaw
Manchester University - Ft. Wayne Campus
Manchester University - North Manchester
Purdue Northwest Hammond Campus
Purdue Polytechnic Anderson
Purdue Polytechnic Columbus
Purdue Polytechnic Kokomo
Purdue Polytechnic New Albany
Purdue Polytechnic Richmond
Purdue Polytechnic South Bend
Purdue University Ft. Wayne
Trine University
University of Notre Dame
University of St. Francis
WBAA - NPR Greater Lafayette
WFWA - PBS Fort Wayne
WNIT - PBS Michiana
Wabash College
Current State:Closed
Start Time:2024-12-31 14:59:01
End Time:2024-12-31 14:59:21
Outgoing Notification TextBackbone GARY-SBND is available following a brief outage. Network engineers have been contacted to investigate. The reason for outage is undetermined.




Upcoming Scheduled Maintenances

Ticket No.:CHG0086941
Subject:Maintenance - I-Light POP IPHE
Source Of Impact: Vendor
Affected:Purdue University
Butler University
Smithville
Internet2
GlobalNOC Systems Colo: ICS Team Gear
Start Time:2025-01-15 12:00:00
End Time:2025-01-16 00:00:00
Outgoing Notification TextNetrality Engineering and vendor partner will be performing maintenance on Generator #1, ATS #1 and ATS #2 at 733 Henry. No outages are expected, however, the entire window is reserved.


Ticket No.:CHG0087246
Subject:Maintenance - I-Light OneControl to Navigator Transition
Source Of Impact: Internal
Affected:n/a
Start Time:2025-01-07 14:00:00
End Time:2025-01-08 14:00:00
Outgoing Notification Text


Ticket No.:CHG0086813
Subject:Maintenance - I-Light Member Ivy Tech Terre Haute
Source Of Impact: Vendor
Affected:Member Ivy Tech Terre Haute
Start Time:2025-01-09 05:01:00
End Time:2025-01-09 11:00:00
Outgoing Notification TextMember Ivy Tech Terre Haute will be at risk while circuit provider Joink performs non-disruptive maintenance. The entire window is reserved.


Ticket No.:CHG0086479
Subject:Maintenance 1 of 2 - I-Light Backbone CLMB-NEWA
Source Of Impact: Vendor
Affected:Backbone CLMB-NEWA
IU School of Medicine Health Science
Indiana State University
Indiana State University Federal Hall
Indiana University Southeast
Indiana University Southeast - Water Tower Square
Ivy Tech Lawrenceburg
Ivy Tech Evansville
Ivy Tech Sellersburg
Ivy Tech Terre Haute
Oakland City University
Purdue Polytechnic New Albany
Rose Hulman Institute of Technology
St. Mary of the Woods College
University of Evansville
University of Southern Indiana
Vincennes University
Vincennes University - Aviation
Vincennes University - Fort Branch
Vincennes University - Indiana Deaf School
Vincennes University - Jasper
Vincennes University - Lebanon
Vincennes University - Plainfield
Wabash College
Start Time:2025-01-09 05:01:00
End Time:2025-01-09 10:00:00
Outgoing Notification TextBackbone CLMB-NEWA will be unavailable while vendor Zayo performs maintenance. The entire window is reserved. Please note this is the first of two maintenance windows.


Ticket No.:CHG0086902
Subject:Maintenance 2 of 2 - I-Light Backbone CLMB-NEWA
Source Of Impact: Vendor
Affected:Backbone CLMB-NEWA
IU School of Medicine Health Science
Indiana State University
Indiana State University Federal Hall
Indiana University Southeast
Indiana University Southeast - Water Tower Square
Ivy Tech Lawrenceburg
Ivy Tech Evansville
Ivy Tech Sellersburg
Ivy Tech Terre Haute
Oakland City University
Purdue Polytechnic New Albany
Rose Hulman Institute of Technology
St. Mary of the Woods College
University of Evansville
University of Southern Indiana
Vincennes University
Vincennes University - Aviation
Vincennes University - Fort Branch
Vincennes University - Indiana Deaf School
Vincennes University - Jasper
Vincennes University - Lebanon
Vincennes University - Plainfield
Wabash College
Start Time:2025-01-10 05:01:00
End Time:2025-01-10 10:00:00
Outgoing Notification TextBackbone CLMB-NEWA will be unavailable while vendor Zayo performs maintenance. The entire window is reserved. Please note this is the second of two maintenance windows.